Activation of the Standby System may be manual or automatic.
Manual activation may be accomplished by:
- Positioning either Flight Control switch to STBY RUD.
- Positioning the Alternate Flaps switch to ARM.
Hydraulic System SGR
System A Using Units
- Ailerons
- Rudder
- Elevator and Elevator Feel
- Flight Spoilers
(Two on each wing)
- Alternate Brakes
- Number 1 Thrust Reverser
- Autopilot A
- Normal Nosewheel Steering
- Landing Gear
- Power Transfer Unit (PTU)
System B Using Units
- Ailerons
- Rudder
- Elevator and Elevator Feel
- Flight Spoilers
(Two on each wing)
- Leading Edge Flaps and Slats
- Normal Brakes
- Number 2 Thrust Reverser
- Autopilot B
- Alternate Nosewheel Steering
- Landing Gear Transfer Unit
- Autoslats
- Yaw Damper
- Trailing Edge Flaps
Automatic operation takes place under these conditions only:
- Loss of System A or B and
- TE flaps extended, and
- airborne, or wheel speed greater than 60 knots, and
- FLT CONTROL switch A or B is ON.