How can the crew determine if one SMYD has failed or both
SMYD’s have failed ?
The AUTO SLAT FAIL light illuminates during Master Caution recall
activation and extinguishes when the Master Caution system is
reset.
If both SMYD computers have failed, the AUTOSLAT FAIL light