With the BUS TRANSFER switch in AUTO, under what condition
would the DC cross bus tie relay isolate DC bus 1 from DC bus 2 ?
At glide slope capture during a flight director or autopilot ILS
approach. This prevents a single DC bus failure from affecting
both NAV receivers and flight control computers.