Main Wheel Well Fire Detection
A single fire detector loop is installed in the main wheel well. As the temperature of the
detector increases to a predetermined limit, the detector senses a fire condition. The
WHEEL WELL fire warning light remains illuminated until the temperature of the detector
has decreased below the onset temperature.
The indications for a main wheel well fire are:
- The fire warning bell sounds.
- Both master FIRE WARN lights illuminate.
- The WHEEL WELL fire warning light illuminates.
Main Wheel Well Fire Protection
Main wheel well fire protection consists of fire detection powered by the No.1 AC Transfer
Bus.
Note: The main wheel well has no fire extinguishing system. The nose wheel well does not
have a fire detection system.